COMET SYSTEM, s.r.o.
Bezrucova 2901
756 61  Roznov pod Radhostem
CZECH REPUBLIC
Tel.: +420 571 653 990

E-mail: info@cometsystem.com


 

Monitoring
Systems
Multiloggers Transmitters
And Regulators
Data
Loggers
Temperature
Recorder with Printer
Portable
Instruments
Temperature
Probes

MS55D DataLogger

code: MS55D
The complete solution for monitoring of temperature, humidity and other values.

Data loggers are designed for measuring, recording, evaluation and subsequent processing of input electrical signals, which are subject to relatively slow changes (> 1s). In conjunction with the appropriate sensors and transducers are suitable for monitoring physical quantities.

The device includes traceable calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO / IEC 17025. The calibration sheet is always loaded as modules.
If the defined required configuration of inputs by, calibration certificate proves calibration inputs according to the required configuration - more than one range for each of the 16 inputs.


Send request
   

Features

Monitoring System ArchitectureData Logger enables to:

  • Measure and process 1 to 16 input variables
  • Each of the 16 channels offers the virtual channel (countable)
  • Acquire autonomous recording of measured values
  • Create alarm conditions
  • Based on the created alarms perform other actions (acoustic, optical signaling, control relay outputs, sending SMS messages, handling telephone dialer, messaging using different protocols Ethernet interface, etc.)
  • On-line monitoring of measured values ​​and states

  

Each from 16 Channels offers:

  • independent hysteresis, delay
  • setting up 4 conditions for an alarm

 

Alarms by:

  • GSM modem
  • Emails
  • Phone dialer
  • Integrated buzzer
  • External siren or light
  • Relay

 

Applications:

  • Food and beverages industry (HACCP)
  • Server rooms, data centers
  • Server rooms, data centers
  • Pharmaceutical industry (GMP)
  • Blood stations, pharmacies
  • Horticulture and cultivation of plants
  • HVAC - heating, ventilation, air conditioning, cooling
  • Building and energy management
    Building automation
  • Research and development
  • Laboratories (GLP)
       

 

Type of Data Logger Inputs

Measured values Module types
Range Accuracy Notes
current  DC A0 4 ... 20mA  ±0.1% FS with source approximately 21V for two-wire transducers with
current loop (e.g. temperature and humidity transducers
Comet).
only galvanic not isolated
A1* 4 ... 20mA for passive sensing of current, Rvst = 14 Ohms
B0* 0 ... 20mA input resistance Rvst = 14 Ohms
B1* 0 ... 1A input resistance Rvst = 0,04 Ohms
B2* 0 ... 5A
AC C0 0 ... 20mA ±1% FS galvanic isolated, sinusoidal signal at a frequency of 50 Hz input resistance Rin by type 0.04 Ohm to 14 Ohms
C1 0 ... 1A  
±1% FS
C2 0 ... 5A
 
 
 
 
 
  voltage
 
 
 
DC D0* 0 ... 100mV  
 
±0.1% FS
 
 
input resistance Rin by a 900 kOhms to 10 Mohms
 
 
 
D1* 0 ... 1V
D2* 0 ... 10V
D4* 0 ... 75V
D5* -10V ... +10V ±0.1% FS (± 20 mV)
 AC E0 0 ... 100mV  
 
±1% FS
 
 
only galvanic isolated, sinusoidal signal at a frequency of 50 Hz input resistance Rin by type 700 kOhms to 10 Mohms
 
 
E1 0 ... 1V
E2 0 ... 10V
E4 0 ... 50V
resistance F* necessary to specify a range ±0.1% FS two-wire connection
temperature probes Pt and Ni Ni1000 J*  -50°C ... +250°C

±0.2°C (-50°C ... 100°C)

Ni1000/6180 ppm, two-wire connection
±0.2% MH (100°C ... 250°C) measuring current of approximately 0.25 mA continuously
Pt100 K* -140°C ... +600°C ±0.2°C (-140°C ... +100°C) Pt100/3850 ppm, two-wire connection
±0.2% MH (+100°C ... +600°C) measuring current of approximately 2 mA continuously
Pt1000 K1*  -140°C ... +600°C ±0.2°C (-140°C ... +100°C) Pt1000/3850 ppm, two-wire connection
±0.2% MH (+100 ... +600°C) measuring current of approximately 0.2 mA continuously
 Pt1000 K3  -10°C ... +50°C ±0.06°C Pt1000/3850 ppm, two-wire connection
measuring current of approximately 0.2 mA continuously. Only galvanically not isolated.
thermocouple K (NiCr-Ni) N* -70°C ... +1300°C  ±0.3% MH + 1.5°C linearized, cold junction compensation, datalogger must be placed in recommendend working position
T (Cu-CuNi) T* -200°C ... +400°C
J (Fe-Co) O* -200°C ... 750°C
S (Pt10%Rh-Pt) P* 0°C ... 1700°C ±0.3% MH +1.5°C(200°C ... 1700°C)
B (Pt30%Rh-Pt) Q* 100°C ... 1800°C ±0.3% MH+1.0°C (300°C ... 1800°C) linearized, without cold junction compensation
binary signal potential-less contact S* binary signal   maximum resistance of closed contact is 1000 ohm
  minimum duration for recording is 200ms
voltage, galvanically isolated  S1  
binary signal
  voltage for „H“ state is 3 V to 30 Vdc @ 9 mA max
  minimum duration for recording: 200ms
  galvanically isolated
pulse counter potential-less contact, galvanically isolated CTU  31 bits, 5kHz max.   voltage change of the counter state is 3V to 24VDC
  backup power, filter bouncing
  galvanically isolated
potential-less contact, open connector CTK 31 bits, 5kHz max.   maximum resistance of closed contact is 10 kOhms
  minimum open contact resistance is 250 kilohms
  backup power, filter bouncing
frequency input voltage signal measurement, galvanically isolated FU    0 ... 5kHz ±(0.2% MH + 1Hz) input voltage for "H": 3V to 24V DC @ 7 mA
minimum duration of input pulse: 30us
resolution 1Hz galvanically isolated
measurement frequency switching contact, galvanically not isolated FK 0 ... 5kHz  
±(0.2% MH + 1Hz)
maximum resistance of closed contact is 10 kOhms
minimum open contact resistance is 250 kOhms
resolution 1Hz minimum duration of input pulse: 30us
RS485 input for serial signal RS485 RP digital transmission   input supports Modbus RTU or Advantech
  connected devices must have the same communication parameters
  input can work with up to 16 devices
  galvanically isolated, MS can be equipped with multiple RF modules

* Inputs marked with asterisk (*) are available also as galvanically isolated.
Galvanic isolation is not designed as safety protection.

   Monitoring system inputs

Figure: communication interface, alarm outputs, connection of power. Ethernet interface is optional.

 

Features of Ethernet Interface:

Ethernet Interface

Ethernet interface  
Data logger is designed for  connection to standard computer network. The 10 and 100Mb/s Ethernet is supported.No need to build new data lines. Thanks this installation cost are essentially reduced and instant easy start of monitoring system operation is enabled.

Modbus TCP

Modbus protocol
Enables to read actually measured values by means of industrial standard Modbus. Data is available in several formats. Protocol is suitable for implementing of MS data logger to SCADA system.

SNMP
SNMPv1 protocol
Actually measured values can be acquired by means of SNMPv1 protocol. MIB tables are available for free.
Designed especially for IT applications and use in “managed” computer networks.
Fast data download

Fast data download
Record download speed was increased four-times from previous MS5 data logger generation.

SOAP
SOAP protocol 
Protocol designed for data logger integration to own www infrastructure. Available actual values can be captured by www server (Apache, IIS) and processed by the user.Communication protocol SOAP version 1.1. is supported. By means of this protocol data logger sends actual values in preset intervals to specified server.
Syslog

Syslog protocol
Syslog message is sent after alarm state or data logger error appears. Syslog is compatible with RFC5424.

Email

E-mail
Data logger sends warning emails up to three different addresses. E-mail is immediately sent after alarm state of monitored technological process appears. User is also informed on error states of device itself (measuring channel error, fulfilling of internal memory, self-test error). SMTP servers requiring autentization are also supported.

XML file

XML file
Actual values can be downloaded to XML file. This option is suitable for data logger integration to SCADA systems.

Display

Data logger display  
Network parameters can be set directly from data logger display. It is possible to change IP address, subnetwork mask and initial gate.

Secured web server

Secured WEB server
WWW server is built in the device. Here it is possible to monitor actual values, alarm states and information on data logger. Also access password for www pages can be entered. WWW pages are user modifiable. Free SDK description is available to create own www pages.

SNMP Trap

SNMP Trap
SNMP Traps are sent after alarm state or device error appears.

Database ready

Database system
Prepared for connection to database system including online values transfer.

Remote conditions

WWW remote conditions
Control of remote condition and relays is enabled also via www interface.

 

Included in Delivery:

  • Data logger including the battery
  • Traceable calibration certificate. Calibration certificate contains calibration of 16 inputs 4-20mA, if it is not defined required configuration of inputs by the user. If required configuration of inputs is defined by the user, calibration certificate proves calibration of inputs in accordance with this required configuration - maximum one range for each of 16 inputs.
  • Calibration of other ranges is optional.
  • USB communication cable
  • Basic manual
  • Free basic Windows software is ready to download at folder Download
     

 

Differences in Features of Data Loggers MS6D and MS55D

  MS55D MS6xx
inputs 1 - 16 hardware input modules 16 software programmable inputs
maximum measured DC current 5A dc 20mA dc
maximum measured DC voltage 75V dc 10V dc
most sensitive measuring range of dc voltage 100mV dc 18mV dc
maximum measured ac current 5A ac -
maximum measured ac voltage 50V ac -
input for measurement of frequency 0 to 5 kHz -
input for counting of pulses yes -
possibility of galvanical isolation of inputs yes only serial input RS485IN
rack version - yes

 

Technical Data

Technical parameters Value
Total memory capacity 2MB (up to 480 000 values)
Memory type internal SRAM, backed-up by Lithium battery
Data logging modes noncyclic - logging stops after filling the memory
cyclic - after filling memory oldest data is overwritten by new
Data logging interval adjustable individually for all input channels from 1 second to 24 hours
Real time clock year, leap year, month, day, hour, minute, second, backed-up by Lithium battery
Input measured values (1 to 16 inputs) are defined for each channel by installed input modules (see table) accordingly to user requirements
Resolution of the AD converter (analog channels) 16 bits, conversion duration approximately 60ms/channel
Communication speed 9600, 19200, 57600, 115200 Bd, 230400* Bd (* applicable for USB, Ethernet)
Power 9 to 30Vdc, 24Vdc recommended
Operating temperature range 0 to +50°C
Dimensions including connectors 215 x 225 x 60 mm
Protection IP20
Weight approximately 800 g
Warranty 3 years
A0 input module for MS data logger dc current 4-20mA
code: M1001
A0 input module for MS data logger dc current 4-20mA
A1 input module for MS data logger dc current 4-20mA
code: M1002
A1 input module for MS data logger dc current 4-20mA
B0 input module for MS datalogger dc current 0-20mA
code: M1003
B0 input module for MS datalogger dc current 0-20mA
B1 input module for MS datalogger dc current 0-1A
code: M1004
B1 input module for MS datalogger dc current 0-1A
B2 input module for MS datalogger dc current 0-5A
code: M1005
B2 input module for MS datalogger dc current 0-5A
C0 input module for MS datalogger ac current 0-20mA, galvanic isolated
code: M1006
C0 input module for MS datalogger ac current 0-20mA, galvanic isolated
C1 input module for MS datalogger ac current 0-1A, galvanic isolated
code: M1007
C1 input module for MS datalogger ac current 0-1A, galvanic isolated
C2 input module for MS datalogger ac current 0-5A, galvanic isolated
code: M1008
C2 input module for MS datalogger ac current 0-5A, galvanic isolated
D0 input module for MS datalogger dc voltage 0-100mV
code: M1009
D0 input module for MS datalogger dc voltage 0-100mV
D1 input module for MS datalogger dc voltage 0-1V
code: M1010
D1 input module for MS datalogger dc voltage 0-1V
D2 input module for MS datalogger dc voltage 0-10V
code: M1011
D2 input module for MS datalogger dc voltage 0-10V
E0 input module for MS datalogger ac voltage 0-100mV, galvanic isolated
code: M1013
E0 input module for MS datalogger ac voltage 0-100mV, galvanic isolated
E1 input module for MS datalogger ac voltage 0-1V, galvanic isolated
code: M1014
E1 input module for MS datalogger ac voltage 0-1V, galvanic isolated
E2 input module for MS datalogger ac voltage 0-10V, galvanic isolated
code: M1015
E2 input module for MS datalogger ac voltage 0-10V, galvanic isolated
F input module for datalogger MS
code: M1017
F input module for datalogger MS
J input module for MS datalogger RTD sensor Ni1000/6180 ppm
code: M1018
J input module for MS datalogger RTD sensor Ni1000/6180 ppm
K input module for MS datalogger RTD sensor Pt100
code: M1019
K input module for MS datalogger RTD sensor Pt100
K1 input module for MS datalogger RTD sensor Pt1000
code: M1020
K1 input module for MS datalogger RTD sensor Pt1000
N input module for datalogger MS
code: M1021
N input module for datalogger MS
O input module for datalogger MS
code: M1022
O input module for datalogger MS
P input module for datalogger MS
code: M1023
P input module for datalogger MS
Q input module for datalogger MS
code: M1024
Q input module for datalogger MS
A1G input module for MS datalogger dc current 4-20mA, galvanic isolated
code: M1025
A1G input module for MS datalogger dc current 4-20mA, galvanic isolated
B0G input module for MS datalogger dc current 0-20mA, galvanic isolated
code: M1026
B0G input module for MS datalogger dc current 0-20mA, galvanic isolated
B1G input module for MS datalogger dc current 0-1A, galvanic isolated
code: M1027
B1G input module for MS datalogger dc current 0-1A, galvanic isolated
B2G input module for MS datalogger dc current 0-5A, galvanic isolated
code: M1028
B2G input module for MS datalogger dc current 0-5A, galvanic isolated
D0G input module for datalogger dc voltage 0-100mV, galvanic isolated
code: M1029
D0G input module for datalogger dc voltage 0-100mV, galvanic isolated
D1G input module for MS datalogger dc voltage 0-1V, galvanic isolated
code: M1030
D1G input module for MS datalogger dc voltage 0-1V, galvanic isolated
D2G input module for MS datalogger dc voltage 0-10V, galvanic isolated
code: M1031
D2G input module for MS datalogger dc voltage 0-10V, galvanic isolated
FG input module for datalogger MS
code: M1033
FG input module for datalogger MS
JG input module for MS datalogger RTD sensor Ni1000/6180 ppm, galvanic isolated
code: M1034
JG input module for MS datalogger RTD sensor Ni1000/6180 ppm, galvanic isolated
KG input module for MS datalogger RTD sensor Pt100, galvanic isolated
code: M1035
KG input module for MS datalogger RTD sensor Pt100, galvanic isolated
K1G input module for MS datalogger RTD sensor Pt1000, galvanic isolated
code: M1036
K1G input module for MS datalogger RTD sensor Pt1000, galvanic isolated
NG input module for datalogger MS
code: M1037
NG input module for datalogger MS
OG input module for datalogger MS
code: M1038
OG input module for datalogger MS
PG input module for datalogger MS
code: M1039
PG input module for datalogger MS
QG input module for datalogger MS
code: M1040
QG input module for datalogger MS
S input module for datalogger MS
code: M1041
S input module for datalogger MS
S1 input module for datalogger MS
code: M1042
S1 input module for datalogger MS
SG input module for datalogger MS
code: M1043
SG input module for datalogger MS
CTU counter input module for logger MS
code: M1044
CTU counter input module for logger MS
CTK counter input module for logger MS
code: M1045
CTK counter input module for logger MS
FU input module for logger MS
code: M1047
FU  input module for logger MS
FK input module for logger MS
code: M1048
FK  input module for logger MS
TG input module for datalogger MS
code: M1053
TG input module for datalogger MS
T input module for datalogger MS
code: M1054
T input module for datalogger MS
D4 input module for MS datalogger dc voltage 0-75V
code: M1055
D4 input module for MS datalogger dc voltage 0-75V
D5 input module for MS datalogger dc voltage -10 to +10V
code: M1056
D5 input module for MS datalogger  dc voltage -10 to +10V
D4G input module for MS datalogger dc voltage 0-75V, galvanic isolated
code: M1057
D4G input module for MS datalogger dc voltage 0-75V, galvanic isolated
D5G input module for MS datalogger dc voltage -10 to +10V, galvanic isolated
code: M1058
D5G input module for MS datalogger dc voltage -10 to +10V, galvanic isolated
E4 input module for MS datalogger ac voltage 0-50V, galvanic isolated
code: M1059
E4 input module for MS datalogger ac voltage 0-50V, galvanic isolated
K3 input module for MS datalogger RTD sensor Pt1000
code: M1060
K3 input module for MS datalogger RTD sensor Pt1000
RP input module for datalogger MS
code: M1061
RP input module for datalogger MS
GD1250 thermocouple "K" wire probe 1m
code: GD1250-1/0
GD1250 thermocouple "K" wire probe 1m
GD1250 thermocouple "K" wire probe 2m
code: GD1250-2/0
GD1250 thermocouple "K" wire probe 2m
GD1250 thermocouple "K" wire probe 3m
code: GD1250-3/0
GD1250 thermocouple "K" wire probe 3m
GD1250 thermocouple "K" wire probe 4m
code: GD1250-4/0
GD1250 thermocouple "K" wire probe 4m
GD260 thermocouple "K" wire probe 1m
code: GD260-1/0
GD260 thermocouple "K" wire probe 1m
GD260 thermocouple "K" wire probe 2m
code: GD260-2/0
GD260 thermocouple "K" wire probe 2m
GD260 thermocouple "K" wire probe 3m
code: GD260-3/0
GD260 thermocouple "K" wire probe 3m
GD260 thermocouple "K" wire probe 4m
code: GD260-4/0
GD260 thermocouple "K" wire probe 4m
GD700 thermocouple "K" wire probe 1m
code: GD700-1/0
GD700 thermocouple "K" wire probe 1m
GD700 thermocouple "K" wire probe 2m
code: GD700-2/0
GD700 thermocouple "K" wire probe 2m
GD700 thermocouple "K" wire probe 3m
code: GD700-3/0
GD700 thermocouple "K" wire probe 3m
GD700 thermocouple "K" wire probe 4m
code: GD700-4/0
GD700 thermocouple "K" wire probe 4m
Pt1000TG8/0, temperature probe, cable 1 m
code: SN104
Pt1000TG8/0, temperature probe, cable 1 m
Pt1000TG8/0, temperature probe, cable 2 m
code: SN105
Pt1000TG8/0, temperature probe, cable 2 m
Pt1000TG8/0, temperature probe, cable 5 m
code: SN108
Pt1000TG8/0, temperature probe, cable 5 m
Pt1000TG8/0, temperature probe, cable 10 m
code: SN113
Pt1000TG8/0, temperature probe, cable 10 m
Pt1000TR050S/0, temperature probe, cable 1 m
code: SN247
Pt1000TR050S/0, temperature probe, cable 1 m
Pt1000TR050S/0, temperature probe, cable 2 m
code: SN248
Pt1000TR050S/0, temperature probe, cable 2 m
Pt1000TR050S/0, temperature probe, cable 5 m
code: SN249
Pt1000TR050S/0, temperature probe, cable 5 m
Pt1000TG7/0, temperature probe, cable 1 m
code: SN164
Pt1000TG7/0, temperature probe, cable 1 m
Pt1000TG7/0, temperature probe, cable 2 m
code: SN165
Pt1000TG7/0, temperature probe, cable 2 m
Pt1000TG7/0, temperature probe, cable 5 m
code: SN166
Pt1000TG7/0, temperature probe, cable 5 m
Pt1000TG7/0, temperature probe, cable 10 m
code: SN167
Pt1000TG7/0, temperature probe, cable 10 m
2301-220/0, temperature probe, cable 1 m
code: SN168
2301-220/0, temperature probe, cable 1 m
2021-150/0, temperature probe, cable 1 m
code: SN169
2021-150/0, temperature probe, cable 1 m
PTS350A-2/0, temperature probe, cable 2 m
code: SN170
PTS350A-2/0, temperature probe, cable 2 m
2034-220/0, temperature probe, cable 1 m
code: SN175
2034-220/0, temperature probe, cable 1 m
2061-200/0, temperature probe, cable 1 m
code: SN178
2061-200/0, temperature probe, cable 1 m
2061-200/0, temperature probe, cable 2 m
code: SN179
2061-200/0, temperature probe, cable 2 m
2061-200/0, temperature probe, cable 5 m
code: SN180
2061-200/0, temperature probe, cable 5 m
2061-200/0, temperature probe, cable 10 m
code: SN181
2061-200/0, temperature probe, cable 10 m
PTS350A-5/0, temperature probe, cable 5 m
code: SN182
PTS350A-5/0, temperature probe, cable 5 m
PTS350A-10/0, temperature probe, cable 10 m
code: SN183
PTS350A-10/0, temperature probe, cable 10 m
Pt1000TGL40/0, temperature probe, cable 1 m
code: SN185
Pt1000TGL40/0, temperature probe, cable 1 m
Pt1000TGL40/0, temperature probe, cable 2 m
code: SN186
Pt1000TGL40/0, temperature probe, cable 2 m
Pt1000TGL40/0, temperature probe, cable 5 m
code: SN187
Pt1000TGL40/0, temperature probe, cable 5 m
Pt1000TGL40/0, temperature probe, cable 10 m
code: SN188
Pt1000TGL40/0, temperature probe, cable 10 m
Pt1000TR160/0, temperature probe, cable 1 m
code: SN199
Pt1000TR160/0, temperature probe, cable 1 m
Pt1000TR160/0, temperature probe, cable 2 m
code: SN200
Pt1000TR160/0, temperature probe, cable 2 m
Pt1000TR160/0, temperature probe, cable 5 m
code: SN201
Pt1000TR160/0, temperature probe, cable 5 m
Pt1000TR160/0, temperature probe, cable 10 m
code: SN202
Pt1000TR160/0, temperature probe, cable 10 m
Pt1000TR160/0, temperature probe, cable 15 m
code: SN203
Pt1000TR160/0, temperature probe, cable 15 m
Pt1000TR160/0, temperature probe, cable 20 m
code: SN204
Pt1000TR160/0, temperature probe, cable 20 m
PTS380K/0 temperature sensor with a stainless steel connection head and connector
code: SN205
PTS380K/0 temperature sensor with a stainless steel connection head and connector
2091-250/0, Stick-in probe, cable 1 m
code: SN210
2091-250/0, Stick-in probe, cable 1 m
2091-250/0, Stick-in probe, cable 2 m
code: SN211
2091-250/0, Stick-in probe, cable 2 m
2091-250/0, Stick-in probe, cable 5 m
code: SN212
2091-250/0, Stick-in probe, cable 5 m
2091-250/0, Stick-in probe, cable 10 m
code: SN213
2091-250/0, Stick-in probe, cable 10 m
2071-030/0, special probe with CINCH connector
code: SN214
2071-030/0, special probe with CINCH connector
Pt1000TG68/0, temperature probe, cable 2 m
code: SN232
Pt1000TG68/0, temperature probe, cable 2 m
Pt1000TG68/0, temperature probe, cable 5 m
code: SN233
Pt1000TG68/0, temperature probe, cable 5 m
Pt1000TG68/0, temperature probe, cable 10 m
code: SN234
Pt1000TG68/0, temperature probe, cable 10 m
Pt1000TR125/0, temperature probe, cable 1 m
code: SN239
Pt1000TR125/0, temperature probe, cable 1 m
Pt1000TR125/0, temperature probe, cable 2 m
code: SN240
Pt1000TR125/0, temperature probe, cable 2 m
Pt1000TR125/0, temperature probe, cable 5 m
code: SN241
Pt1000TR125/0, temperature probe, cable 5 m
Pt1000TR125/0, temperature probe, cable 10 m
code: SN242
Pt1000TR125/0, temperature probe, cable 10 m
Extension cable thermocouple K with female connector, 1meter length
code: SNP03/0
Extension cable thermocouple K with female connector, 1meter length
Extension cable thermocouple K with female connector,2meters
code: SNP06/0
Extension cable thermocouple K with female connector,2meters
Extension cable thermocouple K with female connector,3meters
code: SNP07/0
Extension cable thermocouple K with female connector,3meters
Extension cable thermocouple K with female connector,4meters
code: SNP08/0
Extension cable thermocouple K with female connector,4meters
Extension cable thermocouple K with female connector,5meters
code: SNP09/0
Extension cable thermocouple K with female connector,5meters
Extension cable thermocouple K with female connector,6meters
code: SNP10/0
Extension cable thermocouple K with female connector,6meters
Extension cable thermocouple K with female connector,7meters
code: SNP11/0
Extension cable thermocouple K with female connector,7meters
Extension cable thermocouple K with female connector,8meters
code: SNP12/0
Extension cable thermocouple K with female connector,8meters
Extension cable thermocouple K with female connector,9meters
code: SNP13/0
Extension cable thermocouple K with female connector,9meters
Extension cable thermocouple K with female connector,10meters
code: SNP14/0
Extension cable thermocouple K with female connector,10meters
Extension cable thermocouple K with female connector,11meters
code: SNP15/0
Extension cable thermocouple K with female connector,11meters
Extension cable thermocouple K with female connector,12meters
code: SNP16/0
Extension cable thermocouple K with female connector,12meters
Extension cable thermocouple K with female connector,13meters
code: SNP17/0
Extension cable thermocouple K with female connector,13meters
Extension cable thermocouple K with female connector,14meters
code: SNP18/0
Extension cable thermocouple K with female connector,14meters
Extension cable thermocouple K with female connector,15meters
code: SNP19/0
Extension cable thermocouple K with female connector,15meters
Comet Database Comet Database
code: CDB
System for collecting, alarming and analysing of measured data from all COMET devices.
Software for COMET Monitoring Systems Software for COMET Monitoring Systems
code: SWR003
Software for COMET Monitoring Systems series MS55D and MS6xx.
MS6D data logger MS6D data logger
code: MS6D
The complete solution for monitoring of temperature, humidity and other values.
Multilogger M1320 - thermometer hygrometer with 2 MiniDIN and 2 Terminals Multilogger M1320 - thermometer hygrometer with 2 MiniDIN and 2 Terminals
code: M1320
Universal datalogger with 4 hardware inputs.
Multilogger can be installed permanently to Ethernet network or work as portable device.
Included is traceable calibration certificate in accordance with EN ISO/IEC17025.s portable device.
MS6-Rack data logger MS6-Rack data logger
code: MS6-Rack
The complete solution for monitoring of temperature, humidity and other values. For mounting to 19" rack - one rack unit 1U. Enables to build in the optional MP016 output relays module with 16 relays - see Optional accessories.
Database Viewer for Comet Database Database Viewer for Comet Database
code: DBV
Low cost browser Database Viewer enables several clients to view database from different places on network/internet.