T3111P Compressed air RH+T+Tdp sensor with 4-20mA output

code: T3111P
Humidity, temperature transmitter. T+RH probe from hard anodized duralumin for compressed air up to 25 bars on the cable. Outdoor, indoor use.

Relative humidity, temperature sensors at probe on the cable. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.

The device is supplied with T+RH probe with 1m cable. Cable lengths 2m or 4m available optionally.

Included in delivery:   

    • Traceable calibration certificate
    • Quick start manual
    • Free program TSensor for configuring of the transmitter is ready to Download

Send request
   

Features

Programmable temperature and humidity transmitter is equipped with temperature and relative humidity sensors. Measured values are also converted to other humidity interpretation - dew point temperature, absolute humidity, specific humidity, mixing ratio or specific enthalpy. Degrees Celsius and Fahrenheit are user selectable. Transmitter contains a microprocessor based control circuitry in a durable plastic case with connection terminals and sensors in a probe on a cable. Sensors are protected with filter with stainless steel mesh. Humidity transmitters is equipped with two galvanic isolated 4-20mA outputs. Configuration of outputs and output range are user adjustable. Large dual line LCD for simultaneous display of T+RH or other humidity interpretation is an advantage. Display is possible to switch off. Computerized design ensures temperature compensation of the humidity sensor and fail indication. State-of-the-art capacitive polymer sensor ensures excellent calibration long term stability, inertia against water and condensation. Transmitters are designed for use in non-aggressive environment.

T+RH probe from hard anodized duralumin with 1m cable. Cable lengths 2m or 4m available. 

 

APPLICATIONS - measuring and control of air humidity at:

  • building HVAC management
  • building HVAC automation
  • warehouses
  • glasshouses
  • manufacturers
  • museums, archives, galleries
  • air-conditioned rooms
  • weather stations

Outputs are set to maximum range from the manufacturer (-30 to +105°C, 0 to 100%RH).
To set other range by the user buying of SP003 cable is necessary - see Optional accessory.
Free configuration program TSensor for transmitter adjustment is ready to download anytime.

If different adjustment of outputs is required, please specify required output values (RH, T, Tdp, ..) and required ranges in the order. Adjustment is free of charge.

Any measured value - temperature, relative humidity, dew point temperature, absolute humidity, specific humidity, mixing ratio or specific enthalpy can be assigned to each output of the transmitter. Also identical value can be assigned to both outputs.

Ordering example: Transmitter T3111, output 1: RH 10 to 90%, output 2: temperature 0 to 35°C

 Application wiring of the transmitter

Typical application wiring of dual output transmitter

Calculation of minimum power voltage Uss for proper operation:
Uss min> Uo min + Imax * Rz,
where: Uo min= 9 V
Imax... approximately 20 mA
Rz... sensing resistor (shunt)
Both current loops (I1 and I2) are connected analogically, current loop I1 must be always connected.

 Relative humidity range

Figure: Relative humidity operating range

Technical Data

Technical parameters Value
Output 4-20mA
Measured Value Temperature + Relative Humidity
Construction Type Compressed Air Humidity up to 2.5MPa
Design Industrial
Temperature Measuring Range -30 to 105 °C
Relay Output No
Two-State Input No
Lcd Display Yes
PoE No
Relative humidity range 0 to 100%
Accuracy of relative humidity measurement ±2.5% relative humidity from 5 to 95% at 23°C
Accuracy of temperature output ±0.4°C from -30 to +100°C
±0.4% from reading over +100°C
Available temperature units degrees Celsius, Fahrenheit
Dew point temperature range -60 to +80 °C
Accuracy of dew point temperature output (for more details see instruction manual) ±1.5°C for dew point temperature +10°C and higher at ambient temperature +25°C
Accuracy of dew point temperature output ±2.0°C for dew point temperature 0°C at ambient temperature +25°C
Accuracy of dew point temperature output ±3.0°C for dew point temperature -10°C at ambient temperature +25°C
Accuracy of dew point temperature output ±6.0°C for dew point temperature -20°C at ambient temperature +25°C
Accuracy and range of absolute humidity output ±1.5g/m3 at ambient temperature T < 25°C
range 0 to 400 g/m3
Accuracy and range of specific humidity output ±2g/kg at ambient temperature T < 35°C
range 0 to 550 g/kg
Accuracy and range of mixing ratio output ±2g/kg at ambient temperature T < 35°C
range 0 to 995 g/kg
Accuracy and range of specific enthalpy output ±3kJ/kg at ambient temperature T < 25°C
range: 0 to 995 kJ/kg
Temperature operating range of case with electronics -30 to +80°C
Temperature operating range of LCD display readable to operating temperature +70°C, it is recommended to switch OFF the LCD over +70°C
Range of humidity sensor temperature compensation all temperature range
Current outputs - two-wire connection 4-20mA, galvanic isolated
Configuration of outputs and output range user adjustable from the PC
Filtering ability of sensor cover 0.025mm - filter with stainless steel mesh
Protection of the case with electronics IP65 electronics, IP40 sensors
Power 9-30Vdc
Mechanical connection of probe G1/2 with O-Ring
Length of the probe cable 1m, 2m or 4m optionally
Dimensions display unit 88.5 x 114 x 39.5 mm (W x H x D), probe length 150 mm, probe diameter 18mm
Weight approximately 260g - 1m probe
Warranty 3 years
T3111   RH+T+Tdp cable probe, 1m cable length, output 4-20mA T3111 RH+T+Tdp cable probe, 1m cable length, output 4-20mA
code: T3111
Humidity, temperature transmitter. Outdoor, indoor use.