Did you know that Comet exists in a US version as well?
manufacturer of measuring instruments
English Česky Africa China Español Français Magyar Polski Sweden USA

Intrinsically safe humidity and temperature duct transmitter with 4-20mA output

ATEX certified humidity and temperature transmitter. Use in potentially explosive atmosphere. Duct mount.

Relative humidity, temperature sensors at 150mm stem. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.

ATEX certification for use in potentially explosive environments.

 

  • code
    T3113Ex
  • Warranty
    3 years

Technical data

Measured value

Temperature
Relative humidity
Counted values (dew point…)

TEMPERATURE SENSOR

Measuring range -30 to +125 °C
Accuracy ±0.4 °C
Resolution 0.1 °C

HUMIDITY SENSOR

Measuring range 0 to 100 % RH
Accuracy ±2.5 % RH from 5 to 95 % at 23 °C
Resolution 0.1% RH

DEW POINT

Measuring range -60 to +80 °C
Accuracy ±1.5 °C at ambient temperature T <25 °C and RH >30 %
Resolution 0.1 °C

ATEX CERTIFICATION

Certificate FTZÚ 13 ATEX 0189X
Marking EX ll 3G Ex ic llC T6 Gc

GENERAL TECHNICAL DATA

Operating temperature -30 to +60 °C
Channels internal temperature and humidity sensor
Counted values dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
Output 4-20 mA, galvanic isolated
Range of humidity sensor temperature compensation all temperature range
Configuration of output user adjustable from PC; measured range + value
Power 9-30 Vdc
Protection class IP65 electronics; IP40 sensors
Dimensions 88,5 x 250 x 39,5 mm; stem length 150 mm
Weight approx. 150 g
Warranty 3 years

Optional accessories and download

Zener Barrier  ZbC2+

Zener Barrier ZbC2+

code ZbC2+

cable for transmitter adjustment via USB port

cable for transmitter adjustment via USB port

code SP003

sintered bronze sensor protection

sintered bronze sensor protection

code F0000
plastic sensor protection with stainless filter (gray)

plastic sensor protection with stainless filter (gray)

code F5200
PTFE sensor protection, white

PTFE sensor protection, white

code F5300

Humidity Standard 10%RH, set 5pcs

Humidity Standard 10%RH, set 5pcs

code HM023
Humidity Standard 80%RH, set 5pcs

Humidity Standard 80%RH, set 5pcs

code HM024
Vessel for adjustment and calibration of humidity

Vessel for adjustment and calibration of humidity

code MD046
PP4 Flat circular flange

PP4 Flat circular flange

code PP4
PP90 Right-angled stainless steel flange

PP90 Right-angled stainless steel flange

code PP90
plastic gland for direct mounting of the humidity probe

plastic gland for direct mounting of the humidity probe

code SP004
Tool for easy connection to WAGO terminals 236 for analog output transmitters

Tool for easy connection to WAGO terminals 236 for analog output transmitters

code SP005

Software

download-icon Database Viewer 3.20.0.0 dbapi 21.1
24.33 MB
download-icon Conversions - application for recalculation of values
694.50 KB

Others

download-icon 3D model T3113Ex
2.07 MB
download-icon Terms and Conditions COMET System s.r.o.
133.12 KB

Manuals

download-icon Instruction Manual
1.14 MB
download-icon Quick Start Manual
686.01 KB
download-icon Declaration of Conformity
63.58 KB
download-icon Manual on the issue COMET sensors in potentially explosive atmospheres
1.13 MB
download-icon ATEX Certificate for sensors with 4-20mA output for use in potentially explosive environments
3.26 MB
download-icon ATEX Certificate for sensors with 4-20mA output for use in potentially explosive environments - Supplementary No. 2
180.55 KB

Catalogs

download-icon CATALOG - Analog Sensors with 0-10 V or 4-20 mA output
1.86 MB

Related products

Zener Barrier  ZbC2+

Zener Barrier ZbC2+

code ZbC2+
Intrinsically safe humidity and temperature transmitter with 4-20mA output

Intrinsically safe humidity and temperature transmitter with 4-20mA output

code T3110Ex
Intrinsically safe humidity and temperature transmitter with cable probe, output 4-20mA

Intrinsically safe humidity and temperature transmitter with cable probe, output 4-20mA

code T3111Ex