T3319 Industrial temperature and humidity transmitter - RS232 output

code: T3319
Humidity, temperature transmitter. Outdoor, indoor use.

Humidity, temperature probe on a cable. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.

The device is supplied with T+RH probe with 1m cable. Cable lengths 2m or 4m available optionally.

Included in delivery:


Send request
   

Features

Programmable temperature and humidity transmitter is equipped with temperature and relative humidity sensors. Measured values are also converted to other humidity interpretation - dew point temperature, absolute humidity, specific humidity, mixing ratio or specific enthalpy. Degrees Celsius and Fahrenheit are user selectable. Transmitter contains a microprocessor based control circuitry in a durable plastic case with connection terminals and sensors in a probe on a cable. Sensors are protected with filter with stainless steel mesh. Large dual line LCD for simultaneous display of T+RH or other humidity interpretation is an advantage. Display is possible to switch off. Computerized design ensures temperature compensation of the humidity sensor and fail indication. State-of-the-art capacitive polymer sensor ensures excellent calibration long term stability, inertia against water and condensation. Transmitters are designed for use in non-aggressive environment. 

APPLICATIONS - measuring and control of air humidity at:

  • building HVAC management
  • building HVAC automation
  • warehouses
  • glasshouses
  • manufacturers
  • museums, archives, galleries
  • air-conditioned rooms
  • weather stations

Measured pressure values are converted to RS232 serial output.
Serial output RS232 - transmitter works with ModBus RTU communication protocol or with Advantech ADAM compatible protocol. Protocol is user selectable in special configuration mode by means of the PC. Serial link enables to read actual readings and modify transmitter configuration. Instrument works always in slave mode, i.e. responds only to master device query. Transmitters have the address space available from 1 to 255. Communication speed is 110 to 115200Bd.

SOFTWARE:

  • Comet Database
    Complex solution for data acquisition and analysing. Easy to use and high flexible database software for Comet Transmitters and Regulators.


  • T-Sensor software
    Free configuration utility for Comet Transmitters and Regulators.

  • SensorReader software
    Basic data acquisition utility for Comet Transmitters and Regulators. Software is free for download.

  Online Monitoring system with RS485/232 sensors

Technical Data

Technical parameters Value
Output RS232
Measured Value Temperature + Relative Humidity
Construction Type With T+RH Probe on Cable
Design Industrial
Temperature Measuring Range -30 to 105 °C
Relay Output No
Two-State Input No
Lcd Display Yes
PoE No
Relative humidity range 0 to 100%
Accuracy of relative humidity measurement ±2.5% relative humidity from 5 to 95% at 23°C
Accuracy of temperature output ±0.4°C from -30 to +100°C
±0.4% from reading over +100°C
Available temperature units degrees Celsius, Fahrenheit
Accuracy and range of dew point temperature output - for more details see graphs ±1.5°C at ambient temperature T<25°C and RH>30%
range -60 to +80 °C
Accuracy and range of absolute humidity output ±1.5g/m3 at ambient temperature T < 25°C
range 0 to 400 g/m3
Accuracy and range of specific humidity output ±2g/kg at ambient temperature T < 35°C
range 0 to 550 g/kg
Accuracy and range of mixing ratio output ±2g/kg at ambient temperature T < 35°C
range 0 to 995 g/kg
Accuracy and range of specific enthalpy output ±3kJ/kg at ambient temperature T < 25°C
range: 0 to 995 kJ/kg
Temperature operating range of case with electronics -30 to +80°C
Temperature operating range of LCD display readable to operating temperature +70°C, it is recommended to switch OFF the LCD over +70°C
Range of humidity sensor temperature compensation all temperature range
Communication protocol ModBus RTU and Advantech ADAM compatible protocol
Communication speed 110 to 115200 Bd
Filtering ability of sensor cover 0.025mm - filter with stainless steel mesh
Protection of the case with electronics IP65 electronics, IP40 sensors
Power 9-30Vdc, current consumption approximately 6mA
Length of the probe cable 1m, 2m or 4m optionally
Dimensions display unit 88.5 x 114 x 39.5 mm (W x H x D), probe length 88 mm, probe diameter 18mm
Weight approximately 290g - 1m probe
Warranty 3 years
COMETEO Meteo Shield for Weather Sensors COMETEO Meteo Shield for Weather Sensors
code: F8100
Newly developed meteorological screen for humidity and temperature transmitters. Passive solar radiation and weather shelter for meteo sensors.
T3311 Temperature and humidity probe with RS232 output, internal sensors T3311 Temperature and humidity probe with RS232 output, internal sensors
code: T3311
Ambient temperature, relative humidity transmitter. Outdoor, indoor use.