T2214 Barometric pressure transmitter - 0-10V output

code: T2214
Atmospheric pressure transmitter. Outdoor, indoor use.

Barometric pressure transmitter for outdoor and indoor use.Display reading and pressure output is user selectable in these units: hPa, kPa, mbar, mmHg, inHg, inH2O, PSI, oz/in2.

NEW - AC Power -  now also powered from 24 Vac !

Included in delivery:   

    • Traceable calibration certificate
    • Quick start manual
    • Free program TSensor for configuring of the transmitter is ready to Download

Send request
   

Features

APPLICATIONS - measuring of air pressure at:

  • building HVAC management
  • building HVAC automation
  • warehouses 
  • manufacturers
  • museums, archives, galleries
  • air-conditioned rooms

     

    Output is adjusted to maximum pressure range from the manufacturer.
    To adjust other range by the user buying of SP003 cable is necessary - see Optional accessory.
    Free configuration program TSensor for transmitter adjustment is ready to download anytime.

    If different adjustment of output pressure range is required, please specify required range in the order. Adjustment is free of charge.

 Barometer wiring

Typical application wiring

Uac = 24 Vac

Udc = 15 to 30 Vdc 

Maximum loading current of each voltage output is 0,5 mA.

Technical Data

Technical parameters Value
Output 0-10V
Measured Value Atmospheric Pressure
Construction Type Ambient Air
Design Industrial
Temperature Measuring Range to °C
Relay Output No
Two-State Input No
Lcd Display Yes
PoE No
Maximum measuring range 600 to 1100hPa
Output setting from the manufacturer 800 to 1100hPa
Accuracy ±(1,3hPa+0.06% from adjusted output span) at 23°C from 800 to 1100hPa
Available pressure units hPa, kPa, mbar, mmHg, inHg, inH2O, PSI, oz/in2
Temperature operating range -30 to +80°C
Temperature operating range of LCD display readable to operating temperature +70°C, it is recommended to switch OFF the LCD over +70°C
Voltage output 0-10V
Configuration of output range user adjustable from the PC
IP protection IP54
Power 15-30Vdc, maximum consumption 20mA; 24 Vac
Dimensions 88.5 x 98 x 39.5 mm (W x H x D)
Weight approximately 135g
Warranty 2 years