Did you know that Comet exists in a US version as well?
manufacturer of measuring instruments
English Česky Africa China Español Français Magyar Polski Sweden USA

Battery operated recorders
Dataloggers

Data loggers

Main features

  • accurate measurement of
  • - temperature
  • - humidity
  • - dew point
  • - current (4 – 20 mA)
  • - voltage (0 – 5 V, 0 – 10 V)
  • - pulses
  • - events
  • nonvolatile memory for 32 000 values
  • indication of alarm conditions via email, SMS or visually
  • software for data analysis on PC
  • communication interfaces - USB, RS232, GSM modem, Ethernet
  • rugged design with protection up to IP67
  • battery life up to 7 years

Communication interface

Communication Interface

Measurment

Temperature * Humidity * Current * Voltage * Pulses *

DATALOGGERS COMET measure physical parameters such as TEMPERATURE, HUMIDITY and DEW POINT. Some models have analog input for measuring DC CURRENT or DC VOLTAGE. These allow to measure other physical quantities with third party sensors. Comet system produces also two-state recorders for monitoring the functions of the machine, running of engine, door open / closed, to control technology procedures, etc. These two-state recorders are also available in combination with the measurement above variables, as well as in combination with PULSE counter for monitoring of water, gas and electricity consumption.

Record

The current measured values are stored at preset intervals from 10 seconds to 24 hours. You can store up to 32 000 values. Logging mode can be adjusted as non-cyclic, when logging stops after filling the memory, or cyclic, when the oldest recorded values are overwritten by new ones after the memory is full. Further, the recording can be set to run only when the measured value is outside preset alarm limits. The datalogger can also record MIN / MAX values.

Alarm indication

For each measurement channel can be set upper and lower limits. In case the limits are exceeded an alarm is indicated as the value blinking on the display. You can select continuous alarm mode when the alarm is active only if the critical situation persists, or memory mode when an alarm is still indicated after measured conditions return to normal.

Data Analysis

The recorded data can be transferred to a personal computer in several ways for further analysis. USB or RS232 communication adapters can be used for short distances, it is necessary to bring the logger to the PC. If it is necessary to download data on the place where logger is mounted the data can be stored in a tablet or smart phone using the Android app. The measured data can be also accessed remotely via GSM modem.

People

Battery operated recorders
Mobile Dataloggers

Mobile Dataloggers
connector USB-C for simple connection and battery charging (SMS and CO 2 loggers)

Main features

  • accurate measurement of
  • - temperature
  • - humidity
  • - dew point
  • - events
  • nonvolatile memory for 500 000 records
  • indication of alarm via SMS, 3-colours LEDs
  • easy to use software for data analysis on PC
  • communication interfaces - USB-C snd GSM modem
  • rugged design
  • long battery life up to 6 years
  • logger deployment down to -40°C

Measurment

Temperature * Humidity * Pulses * Events

DATALOGGERS COMET measure physical parameters such as TEMPERATURE, HUMIDITY and DEW POINT. Comet system produces also two-state recorders for monitoring the functions of the machine, running of engine, door open / closed, to control technology procedures, etc. These two-state recorders are also available in combination with the measurement above variables, as well as in combination with PULSE counter for monitoring of water, gas and electricity consumption.

Record

The current measured values are stored at preset intervals from 1 seconds to 24 hours. You can store up to 500 000 values. Logging mode can be adjusted as non-cyclic, when logging stops after filling the memory, or cyclic, when the oldest recorded values are overwritten by new ones after the memory is full. Further, the recording can be set to run only when the measured value is outside preset alarm limits. The datalogger can also record MIN / MAX values.

Alarm indication

For each measurement channel can be set upper and lower limits. In case the limits are exceeded an alarm is indicated as the value blinking on the display. You can select continuous alarm mode when the alarm is active only if the critical situation persists, or memory mode when an alarm is still indicated after measured conditions return to normal.

Data Analysis

The recorded data can be transferred to a personal computer in several ways for further analysis. USB or RS232 communication adapters can be used for short distances, it is necessary to bring the logger to the PC. If it is necessary to download data on the place where logger is mounted the data can be stored in a tablet or smart phone using the Android app. The measured data can be also accessed remotely via GSM modem.

Graph