MS6D data logger

code: MS6D
The complete solution for monitoring of temperature, humidity and other values.

Data loggers are designed for measuring, recording, evaluation and subsequent processing of input electrical signals, which are subject to relatively slow changes (> 1s). In conjunction with the appropriate sensors and transducers are suitable for monitoring physical quantities.

The device includes traceable calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO / IEC 17025. The calibration sheet is always loaded as modules.
If the defined required configuration of inputs by, calibration certificate proves calibration inputs according to the required configuration - more than one range for each of the 16 inputs.


Send request
   

Features

Monitoring System Architecture

Data Logger enables to:

  • 16 software programmable inputs
  • Measure and process 1 to 16 input variables
  • Each of the 16 channels offers the virtual channel (countable)
  • Acquire autonomous recording of measured values
  • Create alarm conditions
  • Based on the created alarms perform other actions (acoustic, optical signaling, control relay outputs, sending SMS messages, handling telephone dialer, messaging using different protocols Ethernet interface, etc.)
  • On-line monitoring of measured values ​​and states

  

Each from 16 Channels offers:

  • independent hysteresis, delay
  • setting up 4 conditions for an alarm

 

Alarms by:

  • GSM modem
  • Emails
  • Phone dialer
  • Integrated buzzer
  • External siren or light
  • Relay

 

Applications:

  • Food and beverages industry (HACCP)
  • Server rooms, data centers
  • Server rooms, data centers
  • Pharmaceutical industry (GMP)
  • Blood stations, pharmacies
  • Horticulture and cultivation of plants
  • HVAC - heating, ventilation, air conditioning, cooling
  • Building and energy management
    Building automation
  • Research and development
  • Laboratories (GLP)
       

 

Types of Data Logger Inputs

Measured values Range Accuracy Note
current DC 4 to 20 mA ±0.1% FS (±0.02mA) it is possible to connect pasive sensors (powered by monitoring system) or active sensor with its own power supply. Input resistance about 110 Ohms.
voltage DC -10V to +10V ±0.1% FS (±10 mV) input resistance about 10MOhms
-1V to +1V ±0.1% FS (±1 mV)
-100mV to +100mV ±0.1% FS (±100 uV)
-18mV to +18mV ±0,1% FS (±18 uV)
resistance two-wire resistance measurement
 0 to 300 Ohms  ±0.1% FS (±0.3 Ohm)

measuring current approximately 0.8 mA @ 50ms pulse

 0 to 3000 Ohms ±0.1% FS (±3 Ohm measuring voltage approximately 0.5mA @ 50ms pulse
 0 to 10000 Ohms ±0.1% FS (±10 Ohm) measuring current approximately 0.1mA @ 50ms pulse
temperature probes Pt and Ni Ni1000 -50°C to +250°C ±0.2°C (-50°C to 100°C) Ni1000/6180 ppm, two-wire connection
±0.2% MH (100°C to 250°C) measuring current approximately 0.5mA @ 50ms pulse
Pt100 -200°C to +600°C  ±0.2°C (-200°C to+100°C) Pt100/3850 ppm, two-wire connection
±0.2% MH (+100°C to +600°C) measuring current approximately 0.8mA @ 50ms pulse
Pt1000  -200°C to +600°C ±0.2°C (-200°C to+100°C) Pt1000/3850 ppm, two-wire connection
±0.2% MH (+100°C to +600°C) measuring current about 0.5mA @ 50ms pulse
thermistor NTC with selectable formula up to maximum thermistor resistance 11000 Ohms according to the used resistance range (see measurement of resistance) the same characteristics for all connected thermistors
default settings:
R25=2252Ω, R80=282.7Ω
thermocouple
 
K (NiCr-Ni) -200°C to 1300°C

±0.3% MH +1.5°C

linearized, with cold junction compensation, datalogger must be placed in recommendend working position
T (Cu-CuNi) -200°C to 400°C
J (Fe-Co) -200°C to 750°C
S (Pt10%Rh-Pt) 0 to 1700°C
N (NiCrSi-NiSiMg) -200°C to 1300°C
B (Pt30%Rh-Pt) 100°C to 1800°C ±0.3% MH+1.0°C (300°C to 1800°C) linearized without cold junction compensation
 
 
binary signal
 
 
potential-less contact binary signal input voltage for state "L" (IN-COM) < 0.8 V
input voltage for state "H" (IN-COM) > 2 V
open collector resistance of closed contact for state "L" (IN-COM) < 1 kOhms
voltage levels resistance of closed contact for state "H" (IN-COM) > 10 kOhms
minimum duration for sensing of change: 200ms
 RS485 input for serial signal RS485
  on request input serves for reading from devices supporting protocol ModBus RTU or Advantech
connected to terminals next to terminals for channel 15 and 16
input can work with 16 devices
Galvanically isolated.

 

   Monitoring system inputs

Monitoring system inputs

Figure: data logger inputs with switch 12Vdc/24 voltage power supply for connecting sensors.
Serial input RS485IN a surcharge.

Figure: communication interface, alarm outputs, connection of power. Ethernet interface is optional.

 

Features of Ethernet Interface:

Ethernet Interface

Ethernet interface  
Data logger is designed for  connection to standard computer network. The 10 and 100Mb/s Ethernet is supported.No need to build new data lines. Thanks this installation cost are essentially reduced and instant easy start of monitoring system operation is enabled.

Modbus TCP

Modbus protocol
Enables to read actually measured values by means of industrial standard Modbus. Data is available in several formats. Protocol is suitable for implementing of MS data logger to SCADA system.

SNMP
SNMPv1 protocol
Actually measured values can be acquired by means of SNMPv1 protocol. MIB tables are available for free.
Designed especially for IT applications and use in “managed” computer networks.
Fast data download

Fast data download
Record download speed was increased four-times from previous MS5 data logger generation.

SOAP
SOAP protocol 
Protocol designed for data logger integration to own www infrastructure. Available actual values can be captured by www server (Apache, IIS) and processed by the user.Communication protocol SOAP version 1.1. is supported. By means of this protocol data logger sends actual values in preset intervals to specified server.
Syslog

Syslog protocol
Syslog message is sent after alarm state or data logger error appears. Syslog is compatible with RFC5424.

Email

E-mail
Data logger sends warning emails up to three different addresses. E-mail is immediately sent after alarm state of monitored technological process appears. User is also informed on error states of device itself (measuring channel error, fulfilling of internal memory, self-test error). SMTP servers requiring autentization are also supported.

XML file

XML file
Actual values can be downloaded to XML file. This option is suitable for data logger integration to SCADA systems.

Display

Data logger display  
Network parameters can be set directly from data logger display. It is possible to change IP address, subnetwork mask and initial gate.

Secured web server

Secured WEB server
WWW server is built in the device. Here it is possible to monitor actual values, alarm states and information on data logger. Also access password for www pages can be entered. WWW pages are user modifiable. Free SDK description is available to create own www pages.

SNMP Trap

SNMP Trap
SNMP Traps are sent after alarm state or device error appears.

Database ready

Database system
Prepared for connection to database system including online values transfer.

Remote conditions

WWW remote conditions
Control of remote condition and relays is enabled also via www interface.

 

Included in Delivery:

  • Data logger including the battery
  • Traceable calibration certificate. Calibration certificate contains calibration of 16 inputs 4-20mA, if it is not defined required configuration of inputs by the user. If required configuration of inputs is defined by the user, calibration certificate proves calibration of inputs in accordance with this required configuration - maximum one range for each of 16 inputs.
  • Calibration of other ranges is optional.
  • USB communication cable
  • Basic manual
  • Free basic Windows software is ready to download at folder Download
     

 

Differences in Features of Data Loggers MS6D and MS55D

  MS55D MS6xx
inputs 1 - 16 hardware input modules 16 software programmable inputs
maximum measured DC current 5A dc 20mA dc
maximum measured DC voltage 75V dc 10V dc
most sensitive measuring range of dc voltage 100mV dc 18mV dc
maximum measured ac current 5A ac -
maximum measured ac voltage 50V ac -
input for measurement of frequency 0 to 5 kHz -
input for counting of pulses yes -
possibility of galvanical isolation of inputs yes only serial input RS485IN
rack version - yes

 

Technical Data

Technical parameters Value
Total memory capacity 2MB (up to 480 000 values)
Memory type internal SRAM, backed-up by Lithium battery
Data logging modes noncyclic - logging stops after filling the memory
cyclic - after filling memory oldest data is overwritten by new
Data logging interval adjustable individually for all input channels from 1 second to 24 hours
Real time clock year, leap year, month, day, hour, minute, second, backed-up by Lithium battery
Resolution of the AD converter (analog channels) 16 bits, conversion duration approximately 60ms/channel
Communication speed 9600, 19200, 57600, 115200 Bd, 230400* Bd (* applicable for USB, Ethernet)
Power 24Vdc, consumption of data logger itself approximately 80 mA
Operating temperature range 0 to +50°C
Dimensions including connectors 215 x 225 x 44 mm (W x D x H)
Protection IP20
Weight approximately 800 g
Warranty 3 years
GD1250 thermocouple "K" wire probe 1m
code: GD1250-1/0
GD1250 thermocouple "K" wire probe 1m
GD1250 thermocouple "K" wire probe 2m
code: GD1250-2/0
GD1250 thermocouple "K" wire probe 2m
GD1250 thermocouple "K" wire probe 3m
code: GD1250-3/0
GD1250 thermocouple "K" wire probe 3m
GD1250 thermocouple "K" wire probe 4m
code: GD1250-4/0
GD1250 thermocouple "K" wire probe 4m
GD260 thermocouple "K" wire probe 1m
code: GD260-1/0
GD260 thermocouple "K" wire probe 1m
GD260 thermocouple "K" wire probe 2m
code: GD260-2/0
GD260 thermocouple "K" wire probe 2m
GD260 thermocouple "K" wire probe 3m
code: GD260-3/0
GD260 thermocouple "K" wire probe 3m
GD260 thermocouple "K" wire probe 4m
code: GD260-4/0
GD260 thermocouple "K" wire probe 4m
GD700 thermocouple "K" wire probe 1m
code: GD700-1/0
GD700 thermocouple "K" wire probe 1m
GD700 thermocouple "K" wire probe 2m
code: GD700-2/0
GD700 thermocouple "K" wire probe 2m
GD700 thermocouple "K" wire probe 3m
code: GD700-3/0
GD700 thermocouple "K" wire probe 3m
GD700 thermocouple "K" wire probe 4m
code: GD700-4/0
GD700 thermocouple "K" wire probe 4m
Pt1000TG8/0, temperature probe, cable 1 m
code: SN104
Pt1000TG8/0, temperature probe, cable 1 m
Pt1000TG8/0, temperature probe, cable 2 m
code: SN105
Pt1000TG8/0, temperature probe, cable 2 m
Pt1000TG8/0, temperature probe, cable 5 m
code: SN108
Pt1000TG8/0, temperature probe, cable 5 m
Pt1000TG8/0, temperature probe, cable 10 m
code: SN113
Pt1000TG8/0, temperature probe, cable 10 m
Pt1000TR050S/0, temperature probe, cable 1 m
code: SN247
Pt1000TR050S/0, temperature probe, cable 1 m
Pt1000TR050S/0, temperature probe, cable 2 m
code: SN248
Pt1000TR050S/0, temperature probe, cable 2 m
Pt1000TR050S/0, temperature probe, cable 5 m
code: SN249
Pt1000TR050S/0, temperature probe, cable 5 m
Pt1000TG7/0, temperature probe, cable 1 m
code: SN164
Pt1000TG7/0, temperature probe, cable 1 m
Pt1000TG7/0, temperature probe, cable 2 m
code: SN165
Pt1000TG7/0, temperature probe, cable 2 m
Pt1000TG7/0, temperature probe, cable 5 m
code: SN166
Pt1000TG7/0, temperature probe, cable 5 m
Pt1000TG7/0, temperature probe, cable 10 m
code: SN167
Pt1000TG7/0, temperature probe, cable 10 m
2301-220/0, temperature probe, cable 1 m
code: SN168
2301-220/0, temperature probe, cable 1 m
2021-150/0, temperature probe, cable 1 m
code: SN169
2021-150/0, temperature probe, cable 1 m
PTS350A-2/0, temperature probe, cable 2 m
code: SN170
PTS350A-2/0, temperature probe, cable 2 m
2034-220/0, temperature probe, cable 1 m
code: SN175
2034-220/0, temperature probe, cable 1 m
2061-200/0, temperature probe, cable 1 m
code: SN178
2061-200/0, temperature probe, cable 1 m
2061-200/0, temperature probe, cable 2 m
code: SN179
2061-200/0, temperature probe, cable 2 m
2061-200/0, temperature probe, cable 5 m
code: SN180
2061-200/0, temperature probe, cable 5 m
2061-200/0, temperature probe, cable 10 m
code: SN181
2061-200/0, temperature probe, cable 10 m
PTS350A-5/0, temperature probe, cable 5 m
code: SN182
PTS350A-5/0, temperature probe, cable 5 m
PTS350A-10/0, temperature probe, cable 10 m
code: SN183
PTS350A-10/0, temperature probe, cable 10 m
Pt1000TGL40/0, temperature probe, cable 1 m
code: SN185
Pt1000TGL40/0, temperature probe, cable 1 m
Pt1000TGL40/0, temperature probe, cable 2 m
code: SN186
Pt1000TGL40/0, temperature probe, cable 2 m
Pt1000TGL40/0, temperature probe, cable 5 m
code: SN187
Pt1000TGL40/0, temperature probe, cable 5 m
Pt1000TGL40/0, temperature probe, cable 10 m
code: SN188
Pt1000TGL40/0, temperature probe, cable 10 m
Pt1000TR160/0, temperature probe, cable 1 m
code: SN199
Pt1000TR160/0, temperature probe, cable 1 m
Pt1000TR160/0, temperature probe, cable 2 m
code: SN200
Pt1000TR160/0, temperature probe, cable 2 m
Pt1000TR160/0, temperature probe, cable 5 m
code: SN201
Pt1000TR160/0, temperature probe, cable 5 m
Pt1000TR160/0, temperature probe, cable 10 m
code: SN202
Pt1000TR160/0, temperature probe, cable 10 m
Pt1000TR160/0, temperature probe, cable 15 m
code: SN203
Pt1000TR160/0, temperature probe, cable 15 m
Pt1000TR160/0, temperature probe, cable 20 m
code: SN204
Pt1000TR160/0, temperature probe, cable 20 m
PTS380K/0 temperature sensor with a stainless steel connection head and connector
code: SN205
PTS380K/0 temperature sensor with a stainless steel connection head and connector
2091-250/0, Stick-in probe, cable 1 m
code: SN210
2091-250/0, Stick-in probe, cable 1 m
2091-250/0, Stick-in probe, cable 2 m
code: SN211
2091-250/0, Stick-in probe, cable 2 m
2091-250/0, Stick-in probe, cable 5 m
code: SN212
2091-250/0, Stick-in probe, cable 5 m
2091-250/0, Stick-in probe, cable 10 m
code: SN213
2091-250/0, Stick-in probe, cable 10 m
2071-030/0, special probe with CINCH connector
code: SN214
2071-030/0, special probe with CINCH connector
Pt1000TG68/0, temperature probe, cable 2 m
code: SN232
Pt1000TG68/0, temperature probe, cable 2 m
Pt1000TG68/0, temperature probe, cable 5 m
code: SN233
Pt1000TG68/0, temperature probe, cable 5 m
Pt1000TG68/0, temperature probe, cable 10 m
code: SN234
Pt1000TG68/0, temperature probe, cable 10 m
Pt1000TR125/0, temperature probe, cable 1 m
code: SN239
Pt1000TR125/0, temperature probe, cable 1 m
Pt1000TR125/0, temperature probe, cable 2 m
code: SN240
Pt1000TR125/0, temperature probe, cable 2 m
Pt1000TR125/0, temperature probe, cable 5 m
code: SN241
Pt1000TR125/0, temperature probe, cable 5 m
Pt1000TR125/0, temperature probe, cable 10 m
code: SN242
Pt1000TR125/0, temperature probe, cable 10 m
Extension cable thermocouple K with female connector, 1meter length
code: SNP03/0
Extension cable thermocouple K with female connector, 1meter length
Extension cable thermocouple K with female connector,2meters
code: SNP06/0
Extension cable thermocouple K with female connector,2meters
Extension cable thermocouple K with female connector,3meters
code: SNP07/0
Extension cable thermocouple K with female connector,3meters
Extension cable thermocouple K with female connector,4meters
code: SNP08/0
Extension cable thermocouple K with female connector,4meters
Extension cable thermocouple K with female connector,5meters
code: SNP09/0
Extension cable thermocouple K with female connector,5meters
Extension cable thermocouple K with female connector,6meters
code: SNP10/0
Extension cable thermocouple K with female connector,6meters
Extension cable thermocouple K with female connector,7meters
code: SNP11/0
Extension cable thermocouple K with female connector,7meters
Extension cable thermocouple K with female connector,8meters
code: SNP12/0
Extension cable thermocouple K with female connector,8meters
Extension cable thermocouple K with female connector,9meters
code: SNP13/0
Extension cable thermocouple K with female connector,9meters
Extension cable thermocouple K with female connector,10meters
code: SNP14/0
Extension cable thermocouple K with female connector,10meters
Extension cable thermocouple K with female connector,11meters
code: SNP15/0
Extension cable thermocouple K with female connector,11meters
Extension cable thermocouple K with female connector,12meters
code: SNP16/0
Extension cable thermocouple K with female connector,12meters
Extension cable thermocouple K with female connector,13meters
code: SNP17/0
Extension cable thermocouple K with female connector,13meters
Extension cable thermocouple K with female connector,14meters
code: SNP18/0
Extension cable thermocouple K with female connector,14meters
Extension cable thermocouple K with female connector,15meters
code: SNP19/0
Extension cable thermocouple K with female connector,15meters
Comet Database Comet Database
code: CDB
System for collecting, alarming and analysing of measured data from all COMET devices.
Software for COMET Monitoring Systems Software for COMET Monitoring Systems
code: SWR003
Software for COMET Monitoring Systems series MS55D and MS6xx.
Ethernet Multilogger M1140 - thermo hygro meter with 4 MiniDIN inputs Ethernet Multilogger M1140 - thermo hygro meter with 4 MiniDIN inputs
code: M1140
Universal datalogger with 4 hardware MiniDIN inputs for connecting temperature and humidity probes.
Multilogger can be installed permanently to Ethernet network or work as portable device.
Included is traceable calibration certificate in accordance with EN ISO/IEC17025.
MS6-Rack data logger MS6-Rack data logger
code: MS6-Rack
The complete solution for monitoring of temperature, humidity and other values. For mounting to 19" rack - one rack unit 1U. Enables to build in the optional MP016 output relays module with 16 relays - see Optional accessories.
MS6R data logger MS6R data logger
code: MS6R
The complete solution for monitoring of temperature, humidity and other values. For desktop use with rubber feet - see Optional accessories. For mounting to 19" rack - one rack unit 1U.
MS55D DataLogger MS55D DataLogger
code: MS55D
The complete solution for monitoring of temperature, humidity and other values.
Database Viewer for Comet Database Database Viewer for Comet Database
code: DBV
Low cost browser Database Viewer enables several clients to view database from different places on network/internet.