Web Sensor T0610 with PoE - remote thermometer with Ethernet interface

code: T0610
Ambient temperature t-line Web sensor with Power over Ethernet feature. Remote alarm.

PoE Web Sensor with built-in temperature sensor. Power over Ethernet feature according IEEE 802.3af is supported.

WiFi Router Easy wireless communication using Web Sensor and optional  Wireless TP-LINK router.

 

Included in delivery:Power over Ethernet


Send request
   

Features

APPLICATIONS:

  • Server rooms monitoring
    Temperature monitoring of the server rooms and rack units, SNMP monitoring, remote alarm by email and Syslog

  • Building HVAC management
    Temperature monitoring of buildings, history data to Comet Database , remote alarm by email or SMS

  • Warehouses
    Temperature monitoring of storage, history data to Comet Database or 3rd party SCADA system

  • Museums, archives, galleries
    Temperature is requested for rooms where old valuable documents are stored, history data to Comet Database, remote alarm by email or SMS

  • Factories and manufacturing
    Temperature monitoring for food processing industry, pharmaceutical industry, aerospace industry, etc.

  • Air-conditioned rooms
    Temperature rising indicates cooling fault, remote alarm by email
  Temperature LCD Ethernet PoE WWW WWW config 1000 values Graph CSV Email Modbus XML SNMP Trap SOAP Syslog SNTP MIN/MAX




P8541 demo

SOFTWARE:

  • Comet Database
    Complex solution for data acquisition and analysing. Easy to use and high flexible database software for Comet Transmitters and Regulators.

  • T-Sensor software
    Free configuration utility for Comet Transmitters and Regulators.

  • SensorReader software
    Basic data acquisition utility for Comet Transmitters and Regulators. Software is free for download.

  • 3rd party software
    Cacti, InTouch, ControlWeb, EasyView, LabVIEW. Support for this software is provided by the 3rd party companies.
  Online Ethernet Monitoring system

FEATURES:

Temperature
Temperature  Web Sensor is designed to measuring from internal temperature sensor. Degrees Celsius and Fahrenheit are user selectable.
Dual line LCD
Ethernet Large dual line LCD for display of temperature is an advantage. Display can be switched off.
Ethernet interface
Ethernet 10Base-T/100Base-TX Ethernet interface via standard RJ45 connector. IP address can be obtain automatically from DHCP server or set manually. Internet protocol version 4 is supported only.
Power over Ethernet
PoE Power over Ethernet according IEEE 802.3af standard. Cost and time to integration can be reduced using Power over Ethernet feature. Only Ethernet infrastructure with PoE switch is needed to get device to work.
WWW server
WWW WWW config Actual measured values are accessible via powerful embedded web server. Web pages are ready for access from mobile devices like smartphones and tablets. Device configuration via web pages is possible too. The device allows you to user customize the design of web pages.
History values memory
1000 values Measured values are stored into history memory according selected time interval. Capacity of the memory is 1000 records for each channel. Values inside history memory are not backuped. Memory is cleared after device restart.
History graphs
Graph Graphs with history values are accessible via web pages. Modern HTML5 canvas graphic component allows to use graphs from thousands of devices. It is not problem show graphs on tablets or smartphones. All modern web browsers are supported - Firefox, Opera, Chrome or Internet Explorer 9.
ModbusTCP protocol
Modbus Modbus protocol for communication with SCADA systems or third party software. Device use Modbus TCP protocol version. Two Modbus clients can be connected to device at one moment.
Actual values via XML
XML XML protocol for actual measured values reading. This protocol is suitable for device integration into 3rd party SCADA systems.
Email
Email Warning email are sent when measured value exceed selected limits. Emails are also send when values returns back into safe range. SMTP authentication is supported, but SSL not. Domain name for SMTP server address is supported. Emails with CSV file attachment can be sent at selected intervals.
History export to CSV
CSV History values can be exported for next processing by the CSV file. CSV file can be processed inside spreadsheet application like Microsoft Excel or OpenOffice Calc. Two formats of CSV file are supported - dot and comma decimal point separators. Timestamps inside CSV file are shown when device time is synchronised by the SNTP server. CSV file can be downloaded from web pages or periodically send as email attachment.
SNMP protocol
SNMP SNMP version 1 protocol for IT infrastructure. Using SNMP protocol you can read actual measured values, alarm status and alarm parameters. Via SNMP protocol is also possible to get last 1000 measured values from history table. MIB tables with OID description are available.
SNMP Trap
Trap SNMP Trap for IT infrastructure. The device allows sending Traps to selected Trap receiver server. Traps are sent in case of alarm on channel or at error states like unable to send email, unable to deliver SOAP message, etc.
SOAP protocol
SOAP The device allows to send currently measured values via SOAP v1.1 protocol. The device sends values in XML format to the web server. The advantage of this protocol is that communication is initialized by the device side. Due to it is not necessary use port forwarding.
Syslog protocol
Syslog Syslog protocol for IT infrastructure monitoring systems. The device allows sending text message to selected Syslog server. Messages are sent in case of alarm on channel or at error states like unable to send email, unable to deliver SOAP message, etc.
SNTP protocol - time synchronization
SNTP Time synchronisation with SNTP server. Actual time is shown at web pages and is necessary for timestamps inside CSV files. Synchronisation interval can be set to one day or to one hour.
MIN/MAX memory
MIN/MAX Memory for minimum and maximum values. Memory is independent on values in history memory. Minimum and maximum values can be cleared according user requirements.

Technical Data

Technical parameters Value
Output Ethernet
Measured Value Temperature
Construction Type Ambient Air
Design Industrial
Temperature Measuring Range -20 to 60 °C
Relay Output No
Two-State Input No
Lcd Display Yes
PoE Yes
Accuracy of temperature output ±0.6°C
Resolution 0.1°C
Measuring interval 2s
Available temperature units degrees Celsius, degrees Fahrenheit
Temperature operating range -20 to +60°C
IP protection IP30
LAN connection RJ-45 connector, 10Base-T or 100Base-TX
Communication protocols WWW, ModbusTCP, SNMPv1, SOAP, XML
Alarm protocols E-mail, SNMP Trap, Syslog
Configuration T-Sensor, WWW configuration
Power Power over Ethernet according to IEEE 802.3af or 5Vdc
Power connector co-axial, diameter 5.5 x 2.1mm
Dimensions 136 x 179 x 45mm (W x H x D), stem length 53mm
Weight approximately 320g
Warranty 2 years
Comet Database Comet Database
code: CDB
System for collecting and analysis of measured data (from all COMET devices).
Database Viewer for Comet Database Database Viewer for Comet Database
code: DBV
Low cost browser Database Viewer enables several clients to view database from different places on network/internet.
Web Sensor T3611 with PoE - remote thermometer hygrometer with Ethernet interface Web Sensor T3611 with PoE - remote thermometer hygrometer with Ethernet interface
code: T3611
Ambient temperature, relative humidity t-line Web sensor with Power over Ethernet feature. Remote alarm.
Web Sensor T4611 with PoE - remote thermometer with Ethernet interface Web Sensor T4611 with PoE - remote thermometer with Ethernet interface
code: T4611
Ambient temperature t-line Web sensor for Pt1000 sensor with Power over Ethernet feature. Remote alarm.