Web sensor T3511P - compressed air remote thermometer hygrometer with Ethernet interface

code: T3511P
Humidity, temperature transmitter. T+RH probe from hard anodized duralumin for compressed air up to 25 bars with 1m cable. Cable lengths 2m or 4m available optionally.

Humidity, temperature probe on a cable. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.

WiFi Router Easy wireless communication using Web Sensor and optional  Wireless TP-LINK router.

 

Included in delivery:


Send request
   

Features

APPLICATIONS:

  • Server rooms monitoring
    Temperature/humidity monitoring of the server rooms and rack units, SNMP monitoring, remote alarm by email and Syslog

  • Building HVAC management
    Temperature/humidity monitoring of buildings, history data to DBS Sensor monitor software, remote alarm by email or SMS

  • Warehouses
    Temperature/humidity monitoring of storage, history data to DBS Sensor monitor software or 3rd party SCADA system

  • Museums, archives, galleries
    Temperature/humidity is requested for rooms where old valuable documents are stored, history data to DBS Sensor monitor software, remote alarm by email or SMS

  • Factories and manufacturing
    Temperature/humidity monitoring for food processing industry, pharmaceutical industry, aerospace industry, etc.

  • Air-conditioned rooms
    Temperature rising indicates cooling fault, remote alarm by email
  Temperature Humidity Computed quantity LCD Ethernet WWW WWW config 1000 values Graph CSV Email Modbus XML SNMP Trap SOAP Syslog SNTPMIN/MAX




P8541 demo

SOFTWARE:

  • Comet Database
    Complex solution for data acquisition and analysing. Easy to use and high flexible database software for Comet Transmitters and Regulators.

  • T-Sensor software
    Free configuration utility for Comet Transmitters and Regulators.

  • SensorReader software
    Basic data acquisition utility for Comet Transmitters and Regulators. Software is free for download.

  • 3rd party software
    TIRS.NET, Cacti, InTouch, ControlWeb, EasyView, LabVIEW. Support for this software is provided by the 3rd party companies.
  Online Ethernet Monitoring system

FEATURES:

Temperature and humidity
Temperature Humidity Web Sensor is designed for measuring from temperature and humidity cable probe. High precision capacitive polymer sensor ensures excellent calibration long term stability, inertia against water and condensation. Web Sensor is designed for use in non-aggressive environment. Degrees Celsius and Fahrenheit are user selectable.
Dew point and computed quantities
Ethernet Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy. User can select one of these interpretation.
Dual line LCD
Ethernet Large dual line LCD for simultaneous display of temperature, relative humidity or other calculated humidity interpretation is an advantage. Displayed values are user selectable. Display can be switched off.
Ethernet interface
Ethernet 10Base-T/100Base-TX Ethernet interface via standard RJ45 connector. IP address can be obtain automatically from DHCP server or set manually. Internet protocol version 4 is supported only.
WWW server
WWW WWW config Actual measured values are accessible via powerful embedded web server. Web pages are ready for access from mobile devices like smartphones and tablets. Device configuration via web pages is possible too. The device allows you to user customize the design of web pages.
History values memory
1000 values Measured values are stored into history memory according selected time interval. Capacity of the memory is 1000 records for each channel. Values inside history memory are not backuped. Memory is cleared after device restart.
History graphs
Graph Graphs with history values are accessible via web pages. Modern HTML5 canvas graphic component allows to use graphs from thousands of devices. It is not problem show graphs on tablets or smartphones. All modern web browsers are supported - Firefox, Opera, Chrome or Internet Explorer 9.
Email
Email Warning email are sent when measured value exceed selected limits. Emails are also send when values returns back into safe range. SMTP authentication is supported, but SSL not. Domain name for SMTP server address is supported. Emails with CSV file attachment can be sent at selected intervals.
History export to CSV
CSV History values can be exported for next processing by the CSV file. CSV file can be processed inside spreadsheet application like Microsoft Excel or OpenOffice Calc. Two formats of CSV file are supported - dot and comma decimal point separators. Timestamps inside CSV file are shown when device time is synchronised by the SNTP server. CSV file can be downloaded from web pages or periodically send as email attachment.
ModbusTCP protocol
Modbus Modbus protocol for communication with SCADA systems or third party software. Device use Modbus TCP protocol version. Two Modbus clients can be connected to device at one moment.
Actual values via XML
XML XML protocol for actual measured values reading. This protocol is suitable for device integration into 3rd party SCADA systems.
SNMP protocol
SNMP SNMP version 1 protocol for IT infrastructure. Using SNMP protocol you can read actual measured values, alarm status and alarm parameters. Via SNMP protocol is also possible to get last 1000 measured values from history table. MIB tables with OID description are available.
SNMP Trap
Trap SNMP Trap for IT infrastructure. The device allows sending Traps to selected Trap receiver server. Traps are sent in case of alarm on channel or at error states like unable to send email, unable to deliver SOAP message, etc.
SOAP protocol
SOAP The device allows to send currently measured values via SOAP v1.1 protocol. The device sends values in XML format to the web server. The advantage of this protocol is that communication is initialized by the device side. Due to it is not necessary use port forwarding.
Syslog protocol
Syslog Syslog protocol for IT infrastructure monitoring systems. The device allows sending text message to selected Syslog server. Messages are sent in case of alarm on channel or at error states like unable to send email, unable to deliver SOAP message, etc.
SNTP protocol - time synchronization
SNTP Time synchronisation with SNTP server. Actual time is shown at web pages and is necessary for timestamps inside CSV files. Synchronisation interval can be set to one day or to one hour.
MIN/MAX memory
MIN/MAX Memory for minimum and maximum values. Memory is independent on values in history memory. Minimum and maximum values can be cleared according user requirements.

 

Technical Data

Technical parameters Value
Output Ethernet
Measured Value Temperature + Relative Humidity
Construction Type Compressed Air Humidity up to 2.5MPa
Design Industrial
Temperature Measuring Range -30 to 105 °C
Relay Output No
Two-State Input No
Lcd Display Yes
PoE No
Relative humidity range 0 to 100%
Accuracy of relative humidity measurement ±2.5% relative humidity from 5 to 95% at 23°C
Accuracy of temperature output ±0.4°C
Resolution 0.1°C, 0.1%RH
Measuring interval 2s
Available temperature units degrees Celsius, degrees Fahrenheit
Computed values dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
Dew point temperature range -60 to +80 °C
Accuracy of dew point temperature output (more details in instruction manual) ±1.5°C for dew point temperature +10°C and higher at ambient temperature +25°C
Accuracy of dew point temperature output ±2.0°C for dew point temperature 0°C at ambient temperature +25°C
Accuracy of dew point temperature output ±3.0°C for dew point temperature -10°C at ambient temperature +25°C
Accuracy of dew point temperature output ±6.0°C for dew point temperature -20°C at ambient temperature +25°C
Range of humidity sensor temperature compensation all temperature range
Temperature operating range of case with electronics -30 to +80°C
IP protection IP30 electronics, IP40 sensors
LAN connection RJ-45 connector, 10Base-T or 100Base-TX
Communication protocols WWW, ModbusTCP, SNMPv1, SOAP, XML
Alarm protocols E-mail, SNMP Trap, Syslog
Configuration T-Sensor, WWW configuration
Filtering ability of sensor cover 0.025mm - filter with stainless steel mesh
Material of the probe duralumin with the black eloxal surface finish
Power 9 to 30Vdc, maximum consumption 1W
Power connector co-axial, diameter 5.5 x 2.1mm
Mechanical connection of probe G1/2 with O-Ring
Length of the probe cable 1m, 2m or 4m optionally
Dimensions display unit 88.5 x 93 x 39.5mm (W x H x D), probe length 150mm, probe diameter 18mm
Weight approximately 260g - 1m probe
Warranty 2 years
Comet Database Comet Database
code: CDB
System for collecting, alarming and analysing of measured data from all COMET devices.
Database Viewer for Comet Database Database Viewer for Comet Database
code: DBV
Low cost browser Database Viewer enables several clients to view database from different places on network/internet.
Web sensor T3511 - remote thermometer hygrometer with Ethernet interface Web sensor T3511 - remote thermometer hygrometer with Ethernet interface
code: T3511
Ambient temperature, relative humidity t-line Web sensor. Remote alarm.