manufacturer of measuring instruments
English Česky Africa China Español Français Magyar Polski Sweden USA UAE

Temperature data logger for 3x thermocouples, 1x external Pt1000 probe and 1x internal sensor, with built-in 4G modem

Datalogger is designed to record temperature from three thermocouples, one Pt1000 probe and one internal temperature sensor. In case of exceeded set limits, SMS and JSON messages can be sent via 4G data connection. Measured values can be sent to the internet storage COMET Cloud, which is a complete monitoring, alarm and analysis system.

It is also possible to set the regular sending of JSON messages to COMET Database, the sending interval is adjustable. Alarms are also indicated locally by LED, LCD and acoustically by built-in beeper.
The recording is performed in a non-volatile electronic memory. The data can be transferred to a PC via included USB-C cable.

The device includes Traceable calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO/IEC 17025 standard.

  • code
    U0246G
  • Warranty
    3 years

Technical data

Measured value

Temperature

TEMPERATURE SENSOR - internal probe

Measuring range -20 to +60 °C
Accuracy ±0.6°C
Resolution 0.1 °C
Response time of temperature measurement (temperature step 20°C, air flow approximately 1m/s) t63 < 6 minutes; t90 < 15 minutes

TEMPERATURE SENSOR - external probe Pt1000

Measuring range -200 to +260 °C
Accuracy ±0.2°C; ±0,2 % of the measurement value in a range of +100 to +260 °C
Resolution 0.1 °C
Response time t90 of temperature measurement (temperature step 20°C, air flow approximately 1m/s) according to the connected probe

TEMPERATURE SENSOR - THERMOCOUPLE TYPE B, J, K, N, S, T

Measuring range for thermocouple K and N -200 to +1300 °C
Measuring range for thermocouple J -200 to +750 °C
Measuring range for thermocouple S 0 to 1700 °C
Measuring range for thermocouple B 250 to 1800 °C, cold junction is not compensated
Measuring range for thermocouple T -200 to +400 °C
Measuring range of DC voltage -70 to +70 mV
Accuracy for types J, K, N, T ± (|0,3 % of the measurement value|+1,5 °C)
Accuracy for types B and S ± (|0,5 % of the measurement value| +5 °C)
Accuracy for DC voltage ± 70 µV
Resolution 0,1 °C
Response time according to the connected thermocouple

GSM MODEM PARAMETERS

LTE Cat 1 LTE FDD/GSM/GPRS/EDGE
Supported network types GSM/GPRS/EDGE 900/1800 MHz
LTE FDD B1/B3/B5/B7/B8/B20

GENERAL TECHNICAL DATA

Operating temperature -30 to +70 °C
Channels 3x thermocouple, 1x external Pt1000
Memory 500,000 values in noncyclic logging mode; 350,000 values in cyclic record mode
Recording interva adjustable from 1 s to 24 h
Interval for measuring and evaluating alarms adjustable 1 s, 10 s, 1 min
Recording mode noncyclic - data logging stops after filling the memory
cyclic - after filling memory oldest data is overwritten by new
Real time clock year, leap year, month, day, hour, minute, second
Power rechargeable Li-Ion battery A8200, 3.6V/5200mAh
Protection class IP20
Dimensions 61 x 93 x 53 mm, with antenna 120 x 93 x 53 mm
Weight approx. 270 g
Warranty 3 years

Optional accessories and download

Thermocouple "K" surface probe, CP500

Thermocouple "K" surface probe, CP500

Temperature range: -65 to 500°C
code CP500
Thermocouple "K" stick-in probe, CZ550

Thermocouple "K" stick-in probe, CZ550

Temperature range: -65 to 550°C
code CZ550
Thermocouple "K" stick-in probe, CZ900

Thermocouple "K" stick-in probe, CZ900

Temperature range: -65 to 1000°C
code CZ900
Thermocouple "K" wire probe, GD1250, without connector, 2 meters

Thermocouple "K" wire probe, GD1250, without connector, 2 meters

Temperature range: -65 to 980°C
code GD1250-2/0
Thermocouple "K" wire probe, GD1250, with connector, 3 meters

Thermocouple "K" wire probe, GD1250, with connector, 3 meters

Temperature range: -65 to 980°C
code GD1250-3
Thermocouple "K" wire probe, GD1250, without connector, 3 meters

Thermocouple "K" wire probe, GD1250, without connector, 3 meters

Temperature range: -65 to 980°C
code GD1250-3/0
Thermocouple "K" wire probe, GD1250, with connector, 4 meters

Thermocouple "K" wire probe, GD1250, with connector, 4 meters

Temperature range: -65 to 980°C
code GD1250-4
Thermocouple "K" wire probe, GD1250, without connector, 4 meters

Thermocouple "K" wire probe, GD1250, without connector, 4 meters

Temperature range: -65 to 980°C
code GD1250-4/0
Thermocouple "K" wire probe, GD260, with connector

Thermocouple "K" wire probe, GD260, with connector

Temperature range: -65 to 260°C
code GD260-1
Thermocouple "K" wire probe, GD260, without connector

Thermocouple "K" wire probe, GD260, without connector

Temperature range: -65 to 260°C
code GD260-1/0
Thermocouple "K" wire probe, GD260, with connector, 2 meters

Thermocouple "K" wire probe, GD260, with connector, 2 meters

Temperature range: -65 to 260°C
code GD260-2
Thermocouple "K" wire probe, GD260, without connector, 2 meters

Thermocouple "K" wire probe, GD260, without connector, 2 meters

Temperature range: -65 to 260°C
code GD260-2/0
Thermocouple "K" wire probe, GD260, with connector, 3 meters

Thermocouple "K" wire probe, GD260, with connector, 3 meters

Temperature range: -65 to 260°C
code GD260-3
Thermocouple "K" wire probe, GD260, without connector, 3 meters

Thermocouple "K" wire probe, GD260, without connector, 3 meters

Temperature range: -65 to 260°C
code GD260-3/0
Thermocouple "K" wire probe, GD260, with connector, 4 meters

Thermocouple "K" wire probe, GD260, with connector, 4 meters

Temperature range: -65 to 260°C
code GD260-4
Thermocouple "K" wire probe, GD260, without connector, 4 meters

Thermocouple "K" wire probe, GD260, without connector, 4 meters

Temperature range: -65 to 260°C
code GD260-4/0
Thermocouple "K" wire probe, GD700, without connector

Thermocouple "K" wire probe, GD700, without connector

Temperature range: -65 to 700°C
code GD700-1/0
Thermocouple "K" wire probe, GD700, without connector, 2 meters

Thermocouple "K" wire probe, GD700, without connector, 2 meters

Temperature range: -65 to 700°C
code GD700-2/0
Thermocouple "K" wire probe, GD700, without connector, 3 meters

Thermocouple "K" wire probe, GD700, without connector, 3 meters

Temperature range: -65 to 700°C
code GD700-3/0
Thermocouple "K" wire probe, GD700, without connector, 4 meters

Thermocouple "K" wire probe, GD700, without connector, 4 meters

Temperature range: -65 to 700°C
code GD700-4/0
Thermocouple "K" insertion probe, GT1150

Thermocouple "K" insertion probe, GT1150

Temperature range: -50 to 1150°C
code GT1150

AC/DC adapter 230Vac to 5Vdc/2.1 A, EU

AC/DC adapter 230Vac to 5Vdc/2.1 A, EU

code A1879eu
AC/DC adapter 230Vac to 5Vdc/2.1 A, UK

AC/DC adapter 230Vac to 5Vdc/2.1 A, UK

code A1879uk
AC/DC adapter 230Vac to 5Vdc/2.1 A, US

AC/DC adapter 230Vac to 5Vdc/2.1 A, US

code A1879us
Accupack A8205 for dataloggers "U"

Accupack A8205 for dataloggers "U"

code A8205

Accredited temperature calibration

Accredited temperature calibration

code SLU001

USB-C cable, 1 meter

USB-C cable, 1 meter

code MP053

Wall holder for datalogger

Wall holder for datalogger

code LP100
Holder for mounting the GSM or CO2 Datalogger on magnetic surfaces

Holder for mounting the GSM or CO2 Datalogger on magnetic surfaces

code LP103

COMET Database

COMET Database

code CDB
COMET Cloud

COMET Cloud

code cloud
COMET Cloud Lite for Android & iOS

COMET Cloud Lite for Android & iOS

code cloud_app
COMET VISION - Analytical Software for Dataloggers and Multiloggers

COMET VISION - Analytical Software for Dataloggers and Multiloggers

code CV
Database Viewer for Comet Database

Database Viewer for Comet Database

code DBV

IoT ready Flat Rate SIM Card

IoT ready Flat Rate SIM Card

code LP105

Software

download-icon Comet Vision Software (2.3.8935.24346 dbapi 21.1)
16.56 MB
download-icon Comet Database One Click Installer (21.1-V)
487.31 MB
download-icon Conversions - application for recalculation of values
694.50 KB

Others

download-icon Terms and Conditions COMET System s.r.o.
133.12 KB

Manuals

download-icon Instruction Manual
3.90 MB
download-icon Quick Start Manual
958.40 KB
download-icon Safety Information
127.81 KB
download-icon Manual for Calibration (accuracy verification) and Adjustment for Dataloggers Uxxxx(M)
427.80 KB
download-icon Declaration of Conformity
104.78 KB

Catalogs

download-icon CATALOG - Dataloggers
3.57 MB
download-icon Catalogue Sheets - COMET GSM Data Loggers
2.33 MB

Related products

COMET Cloud

COMET Cloud

code cloud
COMET Database

COMET Database

code CDB
Temperature data logger for 3x thermocouples, 1x external Pt1000 probe and 1x internal sensor

Temperature data logger for 3x thermocouples, 1x external Pt1000 probe and 1x internal sensor

code U0246
Multilogger - Low Cost Thermometer with 4 Thermocouple Inputs

Multilogger - Low Cost Thermometer with 4 Thermocouple Inputs

code M1200E
Multilogger - Thermometer with 4 Thermocouple inputs and Ethernet port

Multilogger - Thermometer with 4 Thermocouple inputs and Ethernet port

code M1200
Temperature data logger for four external Pt1000 probes

Temperature data logger for four external Pt1000 probes

code U0141
IoT Wireless Temperature Datalogger for 4 external probes, with built-in GSM modem

IoT Wireless Temperature Datalogger for 4 external probes, with built-in GSM modem

code U0141TM
IoT Wireless Temperature Datalogger for 4 external probes, with built-in 2G modem

IoT Wireless Temperature Datalogger for 4 external probes, with built-in 2G modem

code U0141M
Temperature data logger for one external Pt1000 probe

Temperature data logger for one external Pt1000 probe

code U0111
Temperature data logger for two external Pt1000 probes

Temperature data logger for two external Pt1000 probes

code U0121
Dual channel temperature data logger for one external Pt1000 probe with internal temperature sensor

Dual channel temperature data logger for one external Pt1000 probe with internal temperature sensor

code U0122
Temperature data logger with built-in sensor

Temperature data logger with built-in sensor

code U0110
Temperature and humidity data logger with built-in sensors

Temperature and humidity data logger with built-in sensors

code U3120
COMETEO Professional Thermometer Screen for Weather Station Sensor

COMETEO Professional Thermometer Screen for Weather Station Sensor

code F8000