Did you know that Comet exists in a US version as well?
manufacturer of measuring instruments
English Česky Africa China Español Français Magyar Polski Sweden USA

Dual channel logger with pulse and binary input

Data logger is designed for record of pulses and two-state events. Values are stored to a non volatile electronic memory. Data transfer to the personal computer for further analysis is performed via USB, RS232, GSM or Ethernet interface by means of a proper communication adapter.

The device includes Traceable calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO/IEC 17025 standard.

For communication with the PC must be from Optional accessories ordered USB adapter or COM adapter or start/stop magnet if is needed to control logging the other way than directly from computer.

 

  • code
    S7021
  • Warranty
    3 years

Technical data

COUNTER INPUT

Counter range in 16 bits mode 0 to 61 695 values
in 32 bits mode 0 to 2 021 654 527 values
Signal for binary input from potential - less contact or two - state voltage signal
Minimum pulse duration at counter input: 1 ms (shorter pulses may not be recorded)
Maximum frequency on binary input 500 Hz
Current through closed contact 30 µA
Voltage across open contact max 3.6 V
LOW voltage level on binary input 0 to +0,2 V (proud ze vstupu max. 30 µA)
HIGH voltage level on binary input +3 to +30 V, current to input max. 100 nA
Connector for connection of input signals CYESN 9 pins

BINARY INPUT

Minimum pulse duration on binary input 500 ms (shorter pulses will not be recorded)
Maximum frequency on binary input 0,5 Hz (i.e maximum of 5 pulses for 10 s)
Power current of connected contact 3 µA (contact closed)
Voltage across open contact max 3.6 V
LOW voltage level on binary input 0 to +0.2 V, current from input max. 3 µA
HIGH voltage level on binary input +3 to +30 V, current to input max. 100 nA
Connector for connection of input signals CYESN 9 pins

GENERAL TECHNICAL DATA

Operating temperature -30 to +70 °C
Channels 1x counter, 1x binary input
Memory 32,000 values
Recording interval adjustable from 10 s to 24 h
Display and alarm refresh each 10 s
Recording mode noncyclic - data logging stops after filling the memory
cyclic - after filling memory oldest data is overwritten by new
Real time clock year, leap year, month, day, hour, minute, second
Power lithium battery 3.6 V; size AA
Battery life 5 years
Protection class IP67
Dimensions (without connectors) 93 x 64 x 29 mm
Weight (including batteries) approx. 115 g
Warranty 3 years

Optional accessories and download

Lithium battery 3,6V/AA

Lithium battery 3,6V/AA

code A4203

KIT - GSM/GPRS modem LP040 with accessories for Sxxxx, Rxxxx loggers

KIT - GSM/GPRS modem LP040 with accessories for Sxxxx, Rxxxx loggers

code KIT-GSM-L
USB adapter

USB adapter

code LP003
Start/stop magnet

Start/stop magnet

code LP004
COM adapter with protection IP65

COM adapter with protection IP65

code LP012
GSM/GPRS MODEM for data loggers of Sxxxx, Rxxxx, Gxxxx families

GSM/GPRS MODEM for data loggers of Sxxxx, Rxxxx, Gxxxx families

code LP040
Transducer USB/RS232 complete

Transducer USB/RS232 complete

code MP006
Antenna for GSM modem

Antenna for GSM modem

code MP009/1
Wall holder for GPRS modem

Wall holder for GPRS modem

code MP036
DIN Rail 35mm holder for GPRS modem

DIN Rail 35mm holder for GPRS modem

code MP037
Communication cable for GSM modem

Communication cable for GSM modem

code QMS2901
SILEX - USB Device server for communication with COMET dataloggers via Ethernet or Wi-Fi

SILEX - USB Device server for communication with COMET dataloggers via Ethernet or Wi-Fi

code Silex
One time fee for using M2M server - applied for each data logger with modem

One time fee for using M2M server - applied for each data logger with modem

code SLU302

wall holder for datalogger

wall holder for datalogger

code F9000
Self Adhesive Dual Lock

Self Adhesive Dual Lock

code MD036

COMET Database

COMET Database

code CDB
Software for COMET TPrints and GSM modems

Software for COMET TPrints and GSM modems

code SWR001

9pin female connector for signal connection, IP67 protection

9pin female connector for signal connection, IP67 protection

code K0921
9pin female connector for S3541,S50x1,S60x1 signal connection

9pin female connector for S3541,S50x1,S60x1 signal connection

code K0925
Connection adapter for loggers

Connection adapter for loggers

code K0945

Software

download-icon Comet Vision Software (2.3.8801.28020 dbapi 21.1)
16.23 MB
download-icon Android downloder from S/R dataloggers
1.85 MB

Others

download-icon Terms and Conditions COMET System s.r.o.
133.12 KB

Manuals

download-icon Instruction Manual
565.15 KB
download-icon Quick Start Manual
995.74 KB
download-icon Declaration of Conformity
60.37 KB

Catalogs

download-icon CATALOG - Dataloggers
3.57 MB

Related products

Four channel data logger with pulse and two-state inputs

Four channel data logger with pulse and two-state inputs

code U7844
IoT Wireless Four channel Datalogger with pulse and two-state inputs, with built-in 2G modem

IoT Wireless Four channel Datalogger with pulse and two-state inputs, with built-in 2G modem

code U7844M