Remote CO2 concentration with Ethernet interface and two relays

code: H5524

CO2 level transmitter with two output relays.


carbon dioxide

The CO2 measurement is based on a 2-source, 2-beam process. CO2 measurement with long-term stability is guaranteed thanks to the proven non-dispersive infrared (NDIR) CO2 measurement cell. The unique patented auto-calibration procedure compensates for aging of the infrared source and guarantees high reliability, long term stability and eliminates the need of periodical recalibration in the field.

 Included in delivery:

 


Send request

Technical data

Value
Measured value CO2
Range of CO<sub>2</sub> concentration measurement 0 to 2000ppm
Accuracy of CO<sub>2</sub> concentration measurement ±(50ppm +2% from reading) at 25°C and 1013hPa
Optional range of CO2 concentration measurement 0 to 10000ppm ±(100ppm +5% from reading) at 25°C and 1013hPa
Resolution 1ppm
Measuring interval 15s
Temperature operating range -30 to +60°C
IP protection IP30
Number of relay outputs 2
Maximum switching voltage, current and power of relay output 50V, 2A, 60VA
Audible alarm built-in beeper - switchable
LAN connection RJ-45 connector, 10Base-T or 100Base-TX
Communication protocols WWW, ModbusTCP, SNMPv1, SOAP
Alarm protocols E-mail (SMTP authentication is supported), SNMP Trap, Syslog
Configuration T-Sensor, Telnet, keyboard
Power 9 to 30Vdc, power consumption approximately 1W
Power connector co-axial, diameter 5.5 x 2.1mm
Dimensions 136 x 150 x 45mm (W x H x D)
Weight approximately 320g
Warranty 3 years

Features

Applications:

Aplikace - Sklady

Production facilities and warehouses - Monitoring of storage conditions and production processes in the temperature range -200 ° C to + 600 ° C. Sending data to COMET Database or SCADA third-party systems.

Aplikace - Serverovny a datová centra

Data centers, server rooms - Temperature and humidity monitoring, data center monitoring, RACK stands, including flood status reports, opening / closing of doors (windows), motion, smoke. SNMP monitoring, remote alarms by email and Syslog.

Aplikace - Zdravotnictví a laboratoře

Healtcare and laboratories  - Monitoring of storage areas at temperatures up to -200 °C.

Aplikace - Průmysl

Industry and production - monitoring temperature and humidity in food, pharmaceutical, aerospace etc.

Aplikace - Sklady

Food industry - Monitoring of critical processes according to the HACCP standard with the possibility of prompt notification of unforeseen events that could lead to the degradation of the goods.

 

Features description:

* the features may vary depending on the device type
● accurate measurement of Temperature, Relative humidity, Dew point, Atmospheric pressure, CO2, Two-state events
● communication protocols SNMP, Modbus TCP, SOAP, XML
● webserver to display current and recorded values
● alarm indication via email
● selected models with PoE
● data analysis in COMET Database software
 
Záruka 3 roky Kalibrační listComet Database Teplotní čidlo Teplotní čidlo Teplotní čidlo Tlakové čidlo Rosný bod Humidex Reléové výstupy
 
Dvouřádkový LCD displej Akustická signalizace Ethernetové rozhraní Power over Ethernet - PoE WWW server WWW server Historie uložených hodnot Historické grafy E-mail Export historických dat do CSV
 
Modbus TCP protokol Aktuální hodnoty pomocí XML SNMP protokol SNMP Trap SOAP Protokol Syslog protokol SNTP protokol - časová synchronizace Paměť MIN/MAX hodnot